W16×67 vs W16×77

A side-by-side comparison of two AISC wide-flange beams, 16th Edition. Detailing dimensions to the nearest 1/16 in.

W16×77 is the heavier section at 77 lb per foot, versus 67 for W16×67 (10 lb/ft more).

Both are nominally 16 in. deep.

W16×77 has the greater bending strength: section modulus Sx of 134 in³ versus 117, about 15% more.

PropertyW16×67W16×77
Weight67 lb/ft77 lb/ft
Depth (d)16 3/8"16 1/2"
Flange width (bf)10 1/4"10 1/4"
Web thickness (tw)3/8"7/16"
Flange thickness (tf)11/16"3/4"
Area (A)19.6 in²22.6 in²
Moment of inertia (Ix)954 in⁴1110 in⁴
Section modulus (Sx)117 in³134 in³
Plastic modulus (Zx)130 in³150 in³

Open W16×67 in the interactive size chart →

Full detail: W16×67 · W16×77. Verify critical dimensions against the current AISC Steel Construction Manual before fabrication.

Browse more: size comparisons · Steel Beam Size Chart