W18×211 vs W18×234
A side-by-side comparison of two AISC wide-flange beams, 16th Edition. Detailing dimensions to the nearest 1/16 in.
W18×234 is the heavier section at 234 lb per foot, versus 211 for W18×211 (23 lb/ft more).
Both are nominally 18 in. deep.
W18×234 has the greater bending strength: section modulus Sx of 466 in³ versus 419, about 11% more.
| Property | W18×211 | W18×234 |
|---|---|---|
| Weight | 211 lb/ft | 234 lb/ft |
| Depth (d) | 20 5/8" | 21" |
| Flange width (bf) | 11 1/2" | 11 5/8" |
| Web thickness (tw) | 1 1/16" | 1 3/16" |
| Flange thickness (tf) | 1 15/16" | 2 1/8" |
| Area (A) | 62.3 in² | 68.6 in² |
| Moment of inertia (Ix) | 4330 in⁴ | 4900 in⁴ |
| Section modulus (Sx) | 419 in³ | 466 in³ |
| Plastic modulus (Zx) | 490 in³ | 549 in³ |
Open W18×211 in the interactive size chart →
Full detail: W18×211 · W18×234. Verify critical dimensions against the current AISC Steel Construction Manual before fabrication.