W24×306 vs W24×335

A side-by-side comparison of two AISC wide-flange beams, 16th Edition. Detailing dimensions to the nearest 1/16 in.

W24×335 is the heavier section at 335 lb per foot, versus 306 for W24×306 (29 lb/ft more).

Both are nominally 24 in. deep.

W24×335 has the greater bending strength: section modulus Sx of 864 in³ versus 789, about 10% more.

PropertyW24×306W24×335
Weight306 lb/ft335 lb/ft
Depth (d)27 1/8"27 1/2"
Flange width (bf)13 3/8"13 1/2"
Web thickness (tw)1 1/4"1 3/8"
Flange thickness (tf)2 1/4"2 1/2"
Area (A)89.7 in²98.3 in²
Moment of inertia (Ix)10700 in⁴11900 in⁴
Section modulus (Sx)789 in³864 in³
Plastic modulus (Zx)922 in³1020 in³

Open W24×306 in the interactive size chart →

Full detail: W24×306 · W24×335. Verify critical dimensions against the current AISC Steel Construction Manual before fabrication.