W44×230 vs W44×262

A side-by-side comparison of two AISC wide-flange beams, 16th Edition. Detailing dimensions to the nearest 1/16 in.

W44×262 is the heavier section at 262 lb per foot, versus 230 for W44×230 (32 lb/ft more).

Both are nominally 44 in. deep.

W44×262 has the greater bending strength: section modulus Sx of 1110 in³ versus 971, about 14% more.

PropertyW44×230W44×262
Weight230 lb/ft262 lb/ft
Depth (d)42 7/8"43 1/4"
Flange width (bf)15 3/4"15 3/4"
Web thickness (tw)11/16"13/16"
Flange thickness (tf)1 1/4"1 7/16"
Area (A)67.8 in²77.2 in²
Moment of inertia (Ix)20800 in⁴24100 in⁴
Section modulus (Sx)971 in³1110 in³
Plastic modulus (Zx)1100 in³1270 in³

Open W44×230 in the interactive size chart →

Full detail: W44×230 · W44×262. Verify critical dimensions against the current AISC Steel Construction Manual before fabrication.