W6×9 vs W6×12

A side-by-side comparison of two AISC wide-flange beams, 16th Edition. Detailing dimensions to the nearest 1/16 in.

W6×12 is the heavier section at 12 lb per foot, versus 9 for W6×9 (3 lb/ft more).

Both are nominally 6 in. deep.

W6×12 has the greater bending strength: section modulus Sx of 7.31 in³ versus 5.56, about 31% more.

PropertyW6×9W6×12
Weight9 lb/ft12 lb/ft
Depth (d)5 7/8"6"
Flange width (bf)4"4"
Web thickness (tw)3/16"1/4"
Flange thickness (tf)3/16"1/4"
Area (A)2.68 in²3.55 in²
Moment of inertia (Ix)16.4 in⁴22.1 in⁴
Section modulus (Sx)5.56 in³7.31 in³
Plastic modulus (Zx)6.23 in³8.3 in³

Open W6×9 in the interactive size chart →

Full detail: W6×9 · W6×12. Verify critical dimensions against the current AISC Steel Construction Manual before fabrication.

Browse more: size comparisons · Steel Beam Size Chart